-40%

Dental Imaging System RVG Digital X-Ray Sensor/Portable X-Ray Machine Equipment

$ 279.83

Availability: 19 in stock
  • Restocking Fee: No
  • Item must be returned within: 30 Days
  • Intended Use/Discipline: Dental Laboratory
  • Warranty: 1 Year
  • MPN: CGQ1180300411
  • Brand: Unbranded
  • Refund will be given as: Money Back
  • Condition: New
  • Return shipping will be paid by: Buyer
  • Modified Item: No
  • Custom Bundle: No
  • Country/Region of Manufacture: China
  • Sensor Size: 26.5mm×32mm×11.7mm
  • All returns accepted: Returns Accepted

    Description

    VXS2121
    Features

    The product is mainly composed of a sensor, an adaptor, a USB connection cable and workstation software. Working together with an X-ray equipment, the Product is intended to make X-ray radiography in dental clinics or veterinary
    clinics

    Sensor size Suitable for child

    adult single tooth

    and
    pets
    .
    Hardware Requirements

    Central Processor: Intel Core i3 or higher
    Internal Memory: 4GB or higher
    Hard Disk: 80GB or higher
    Display: 1280X1024
    USB interface: two
    Keyboard: One
    Mouse: One
    Software Requirement
    Operating Software

    Windows 7 SP1,8,10 32/64bit
    Runtime: .Net Framework 4.6 or higher, VC++ 2015
    Specification

    Product Name: Image
    RVG
    x-ray
    Sensor
    Product Model

    XVS2121
    Operating Voltage:5VDC
    Input power

    500mW
    Spatial Resolution

    ≥7Lp/mm
    Low contrast resolution

    Able to display holes with 1mm, 1.5mm, 2mm and
    2.5mm diameter on the 0.5mm-thick aluminium foil
    Image uniformity ≤2%
    Effective image area

    20.16*20.16mm
    Sensor Size

    26.5mm
    ×
    32mm
    ×
    11.7mm
    Adaptor Size

    60mm
    ×
    40mm
    ×
    29.2mm
    Total Cable Length: 3 m (sensor cable + control box cable to PC)
    Warranty:1 Year
    Accessory :
    Digital sensor: 1 Set
    USB cable :1 PC
    U Disk: 1PC
    Disposable protective sheath: 1 Box

    500

    Silicon loop: 1 PC
    Sensor holder: 1 PC
    Aluminum plate:1 PC (40*40*6mm)
    BLX-5
    Feature:
    1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube
    3.) No protective operation room is needed when installing the complete machine.
    4.) Flexible adjustment of position and angle of handpiece
    5.) Compact in volume, light in weight, convenient for carrying
    6.) Time is adjustable, high contrast of picture, imaging in focus
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor.
    Specifications:
    Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
    Operation of the Main Unit:
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box
    LK-C27
    Feature:
    1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube
    3.) No protective operation room is needed when installing the complete machine
    4.) Flexible adjustment of position and angle of handpiece
    5.) Compact in volume, light in weight, convenient for carrying
    6.) Time is adjustable, high contrast of picture, imaging in focus
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor
    Specifications:
    Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
    Operation of the Main Unit:
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box
    BLX-5(8Plus)
    Product introduction:
    This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays).Using a Toshiba 0.3 micro-focus tube.The tube voltage frequency of this machine is 30 KHz,and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
    TECHNICAL SPECIFICATIONS:
    Tube Voltage
    60kV
    Tube Current
    1mA
    Time Exposure
    1~~9s
    High pressure generator
    30kHz DC
    Rated Power
    60w
    Focal Spot To Skin Distance
    >20CM
    Focus Spot Size
    0.3mm(TOSHIBA)
    Charger Input Voltage
    AC110V~220V
    Supply Frequency
    50Hz±1%
    Radiation Leakage
    <20ugy/h
    Battery
    24V DC 8000MA
    Weight
    4.3KG
    Dimensions
    37 cm×31 cm×28cm (L×W×H)
    Reference of the Angles :
    Tooth
    Upper
    Lower
    1-2
    42
    -15
    3
    45
    -18
    4-5
    30
    -10
    6-8
    28
    -5
    Reference of the time of exposure:
    Tooth
    Adult
    Child
    Central & Lateral
    0.8-1.2
    0.8-1.0
    Cuspid & 1st Bicuspid
    1.2-1.4
    1.0- 1.2
    Upper 5,6
    1.6-1.8
    1.4-1.6
    Upper 7,8
    3.0-3.5
    2.8-3.3.
    Lower 5,6
    1.8-2.0.
    1.6-1.8
    Lower 7,8
    2.0-2.5
    1.8-2.3
    Packing List:
    Main machine 1pc
    Power line 1pc
    User manual 1pc
    Operation of the Main Unit :
    Upon receiving,open the box and check the product for possible damage during shipping.
    Make sure the fittings on the encasement list are packaged within the box.
    Install the blue ray tube to the foreside of the ball head,then tighten it.
    Turn on the Power;the pilot lamp will be light up.During this time,the digital tube will show the fore setting time. Now the equipment is in standby mode.
    Setting the time (Skip to next step if unneeded) Use the "SET","+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 1-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
    Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
    After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)
    After exposure to the tube,press the start button again in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray,so the dental films can be used again).
    Repeat step 6 to reset the picturing time.To repeat the picturing process,please repeat steps 7 to 9.
    Turn the power off when the work is finished,press POWER, making sure the pilot lamp is off.Don't keep the machine long in standby mode.
    Points for Attention:
    Make sure the angle of film,tooth,and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    Remember to turn the power 0ff when work is done.
    Charge the battery if the machine cannot work and the red lamp lignt.
    After turning the power on,wait one minute before taking pictures,this allows the ray to provide a steady output.
    The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
    When taking pictures,the ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
    Use high quality tooth film and developing liquid to make clear pictures.
    Handle the ball head gently while in use,so as not to damage the delicate component.
    We usually set the time between 3-8 seconds when taking pictures,but the actual time of ray output is 0.2-0.5 seconds.
    If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
    Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
    Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    Other requests accordance with the scope of the technical parameters.
    Please read the manual carefully before using
    SHIPS FREE *FROM* THE USA *TO* THE USA!!!
    No months-long wait from overseas!

    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    Seller name:Dentistlove
    City,State:GuangDong,China
    Telephone number:075523387589
    ♞Handling
    We will ship all orders within
    3 business days
    of payment.
    ✈Delivery
    Most items are delivered within 3-5 business days, We generally surpass our projected shipping time! See our FEEDBACK! We Do Not Ship Outside of the Continental US. For your protection and to ensure consistency in the Marketplace, all orders are shipped to your
    EBAY address
    provided at the time of sale. So please ensure it is up to date prior to finalizing your purchase. We are not responsible for undeliverable/incorrect addresses. Purchases made to US protectorates, AFO/APOs will not be processed and will be denied during the checkout process.
    ♟Return Policy
    All items qualify for returns within 30 days of receipt. Please be sure to contact us for return instructions prior to returning any item. Restocking fees of up to 15% may apply to items that are not defective, ordered by accident, or returned for a refund rather than a replacement. Buyer is responsible for return shipping on any item that is not damaged.
    ☻ Feedback
    We take our reputation seriously, we buy and sell online, so we understand the value of trust.
    If you are unsatisfied with your order, please contact us
    and we will work with you to resolve it to your satisfaction.

    ADDITIONAL TERMS
    In the unlikely event, there is an issue with our inventory, you will be provided the option of an immediate refund or substitution. In some cases, we will ship from affiliate distributors in order to fill orders in a timely manner.
    PLEASE do not leave negative feedback before giving us a chance to work through an issue. We GUARANTEE a reasonable solution on all orders.
    Re: K192233
    Trade/Device Name: LED Curing Light
    Regulation Number: 21 CFR 872.6070
    Regulation Name: Ultraviolet Activator for Polymerization
    Regulatory Class: Class II
    Product Code: EBZ
    Dated: December 7, 2019
    Received: December 16, 2019