Dental RVG X-ray Digital X-Ray IRVG Sensor + X-Ray Machine BLX-5

$ 681.1

Availability: 100 in stock
  • MPN: CG1180300411
  • Condition: New
  • Country/Region of Manufacture: China
  • Sensor Size: Size 1
  • Item must be returned within: 60 Days
  • Brand: Unbranded
  • Restocking Fee: No
  • Return shipping will be paid by: Buyer
  • All returns accepted: Returns Accepted
  • Intended Use/Discipline: Dental Laboratory
  • Refund will be given as: Money Back

    Description

    1180300411    (VXS2121)    SensorSize:26.5×32×11.7mm
    Dental and pets X-ray Digital RVG Sensor
    Features:
    The product is mainly composed of a sensor, an adaptor, a USB connection cable and workstation software. Working together with an X-ray equipment, the Product is intended to make X-ray radiography in dental clinics or veterinary clinics,Sensor size Suitable for child(adult single tooth)and pets.
    Hardware Requirements:
    Central Processor: Intel Core i3 or higher
    Internal Memory: 4GB or higher
    Hard Disk: 80GB or higher
    Display: 1280X1024
    USB interface: two
    Keyboard: One
    Mouse: One
    Software Requirement
    Operating Software:Windows 7 SP1,8,10 32/64bit
    Runtime: .Net Framework 4.6 or higher, VC++ 2015
    Specification:
    Product Name: Image RVG x-ray Sensor
    Product Model:XVS2121
    Operating Voltage:5VDC
    Input power:500mW
    Spatial Resolution:≥7Lp/mm
    Low contrast resolution :Able to display holes with 1mm, 1.5mm, 2mm and
    2.5mm diameter on the 0.5mm-thick aluminium foil
    Image uniformity ≤2%
    Effective image area: 20.16*20.16mm
    Sensor Size:26.5mm×32mm×11.7mm
    Adaptor Size:60mm×40mm×29.2mm
    Total Cable Length: 3 m (sensor cable + control box cable to PC)
    Warranty:1 Year
    Accessory :
    Digital sensor: 1 Set
    USB cable :1 PCS
    U Disk: 1PCS
    Disposable protective sheath: 1 Box(500)
    silicon loop: 1 PCS
    Sensor holder: 1 PCS
    Aluminum plate:1 PCS (40*40*6mm)
    X-Ray
    Features:
    1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
    2.) Toshiba 0.3mm x 0.3mm micro-focus tube
    3.) No protective operation room is needed when installing the complete machine
    4.) Flexible adjustment of position and angle of handpiece
    5.) Compact in volume, light in weight, convenient for carrying
    6.) Time is adjustable, high contrast of picture, imaging in focus
    7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
    8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
    9.) Non-film inspection and storage can be realized when corresponding to a sensor
    Specifications
    Voltage: 110v±10% and 220V±10%
    Power: 24V 8000MA
    Charger: 220V/110V, 50Hz
    Tube current: 0.1mA
    Rating: 60W
    Frequency: 30 KHz
    Exposure time: 1-9 seconds optional
    Leak radiation: < 20μgy/h(12lb)
    Focus Skin Distance: >20cm
    Tube voltage: 60KV
    Relative Humidity(RH) < 80%
    Storage conditions: 5-40 degrees Celsius, relative Humidity
    Net weight: 5.5 kg
    Dimension: 47 x 42 x 19 cm
    Content:
    Main Unit x 1
    Dental Film Position x 1
    Charger x 1
    English Manual x 1
    Warranty Card x 1
    Operation of the Main Unit
    1. Upon receiving, open the box and check the product for possible damage during shipping.
    2. Make sure the fittings on the encasement list are packaged within the box.
    3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw
    4. After the Main Unit and ball head are perfectly fit together, plug in the international standard electrical source, grounding is strongly recommended.
    5. Turn on the Power; the pilot lamp will be light up.During this time, the digital tube of the main unit will show the fore setting time. Now the equipment is in standby mode.
    6. Setting the time (Skip to next step if unneeded) Use the "SET", "+", and" -" buttons to reset the time as follows: press SET, the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.5-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
    7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
    8. Keep the ball head plumb to the tooth projection position; Have the ball head, tooth, and tooth film steadily mutually plumb.
    9. After positioning, use theEXP on the main Unit, the remote controller, or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press)
    10. After exposure to the tube, release the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray, so the dental films can be used again).
    Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9.
    11. Turn the power of the main unit off when the work is finished, press POWER, making sure the pilot lamp is off. Don't keep the main unit long in standby mode.
    Points for Attention
    1. Make sure the angle of film, tooth, and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
    2. Remember to turn the power offwhen work is done.
    3. Change the battery if the remote controller loses its functioning or if the remote's distance is shorted.
    4. After turning the power on, wait one minute before taking pictures, this allows the ray to provide a steady output.
    5. The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs,  it will not be able to carry out the normal work of filming.
    6. When taking pictures, the EXP button could stop the objection and then the machine goes back to the preparation mode.
    7. Use high quality tooth film and developing liquid to make clear pictures.
    8. Handle the ball head gently while in use, so as not to damage the delicate component.
    9. Do not pull hard on the cable which connects the ball head to the main unit.
    10. The cable connecting the ball head to the main unit cannot bear the weight of the ball head, so do not raise the ball head by holding the cable, it will cause damage.
    11. We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output is 0.2-0.5 seconds.
    12. If a situation occurs,  preventing the machine from taking regular pictures,  contact the seller to solve the problem instead of trying to service the product yourself.
    13. Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. While, because the liquid is not allowed to ship by carrier normal, so we take it out before ship, look forward to your understanding.
    14. Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
    15. Other requests accordance with the scope of the technical parameters.
    16. Please read the manual carefully before using.
    FDA Statement
    The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid it on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
    The item has been cleaned and handled in accordance with the manufacturer’s instructions
    Proprietary Name:    X-Ray Film Holder
    Classification Name:    HOLDER, FILM, X-RAY
    Product Code:    EGZ
    Device Class:    1
    Regulation Number:    872.1905
    Medical Specialty:    Dental
    Owner/Operator Number:    10054767
    Establishment Operations:    Manufacturer