-40%
Pro Dental Digital X-Ray Sensor Imaging System Pets RVG/ X-Ray Machine Low Dose
$ 279.83
- Description
- Size Guide
Description
X ray SensorFeatures:
The product is mainly composed of a sensor, an adaptor, a USB connection cable and workstation software. Working together with an X-ray equipment, the Product is intended to make X-ray radiography in dental clinics or veterinary clinics,Sensor size Suitable for child(adult single tooth)and pets.
Hardware Requirements:
Central Processor: Intel Core i3 or higher
Internal Memory: 4GB or higher
Hard Disk: 80GB or higher
Display: 1280X1024
USB interface: two
Keyboard: One
Mouse: One
Software Requirement
Operating Software:Windows 7 SP1,8,10 32/64bit
Runtime: .Net Framework 4.6 or higher, VC++ 2015
Specification:
Product Name: Image RVG x-ray Sensor
Product Model:XVS2121
Operating Voltage:5VDC
Input power:500mW
Spatial Resolution:≥7Lp/mm
Low contrast resolution :Able to display holes with 1mm, 1.5mm, 2mm and
2.5mm diameter on the 0.5mm-thick aluminium foil
Image uniformity ≤2%
Effective image area: 20.16*20.16mm
Sensor Size:26.5mm×32mm×11.7mm
Adaptor Size:60mm×40mm×29.2mm
Total Cable Length: 3 m (sensor cable + control box cable to PC)
Warranty:1 Year
Accessory :
Digital sensor: 1 Set
USB cable :1 PCS
U Disk: 1PCS
Disposable protective sheath: 1 Box(500)
silicon loop: 1 PCS
Sensor holder: 1 PCS
Aluminum plate:1 PCS (40*40*6mm)
BLX-5(8PLUS)
x ray machine
p
roduct introduction:
This model combines the advantages of similar products found at home and abroad; it eliminates the shortcomings of the on-frequency X-ray machine (high current intensity and excess amounts of scrap x-rays)
.
U
s
ing a Toshiba
0.3
micro-focus tube
.
The
tu
be voltage
fre
quency of this machine is 30 KHz
,
and the tube current is 1 MA. The radiation scope is at an angle of 24 degrees
,
located within a distance of 1.2 meters ahead. This is an innovative Chinese design named the "Green X-ray Machine."
TECHNICAL SPECIFICATIONS:
Tube Voltage
65kv
Tube Current
1
mA
Time Exposure
0.1
~~
1.8
s
High pressure generator
30
kHz DC
Rated Power
60w
Focal Spot To Skin Distance
>20CM
Focus Spot Size
0.
3
mm(TOSHIBA)
Charger Input Voltage
AC1
1
0V~2
2
0V
Supply Frequency
30
Hz
Radiation Leakage
<2
0ug
y/h
Battery
24V DC
2600MA
Weight
4.3
KG
Dimensions
37
cm×
31
cm×
28
cm (L×W×H)
Reference of the Angles :
'
Tooth
Upper
Lower
1-2
42
-15
3
45
-18
4-5
30
-10
6-8
28
-5
Reference of the time of exposure:
Tooth
Adult
Child
Central & Lateral
0.
2
-
0.3
s
0.2-0.3
s
Cuspid & 1
st
Bicuspid
0.3
-
0.4
s
0.3
-
0.4
s
Upper 5,6
0.5
-
0.6
s
0.5
-
0.6
s
Upper 7,8
1.3
-
1.8
s
1.2
-
1.5
.
s
Lower 5,6
0.5
-
0.6
s
0.4
-
0.5
s
Lower
7,8
0.6
-
0.8
s
0.5
-
0.7
s
Packing List:
Main machine
1pcs
Power line
1pcs
User manual
1pcs
Operation of the Main Unit :
Upon re
ceiv
ing,open the box and check the product for possible damage during shipping.
Make sure the fittings on the encasement list are packaged within the box.
Turn on the Power
;
the pilot lamp will be light up
.
During this time,the digital tube will show the fore se
ttin
g time. Now the equipment is in standby mode.
Sett
ing the time (Skip to next step if unneeded)
"+",and" -" buttons to reset the time as follows: press SET,the pilot lamp above is illuminated, the machine is now in the time setting mode
→
then press "+" and" -" to set the time needed (time range is
0.1
-
1.8
seconds); The equipment is now in standby mode.
Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the t
oot
h)
Keep the ball head plumb to the tooth projection position; Have the ball head,tooth, and tooth film steadily mutually plumb.
After positioning,use the ON/OFF on the main Unit, to take pictures. (Notice: gently press 0.5 sec to turn it on)
Points for Attention
:
Make sure the angle of film,tooth,and ball head are properly aligned when taking a picture.
Keep them steady until the last step of picturing
;
making sure that there is no change in any of their positions.
Remember to turn the power 0
ff
when work is done.
Cha
r
ge the battery if t
he machine cannot work and the red lamp lignt
After turning the power on,wait one minute before taking pictures,this allows the ray to provide a steady ou
tp
ut.
The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of
fil
ming.
When taking pictures,
the
ON/OFF button could stop the objection and then the machine goes back to the preparation mode.
Use high quality tooth film and developing liquid to make clear pictures.
Handle the ball head gently while in use,so as not to damage the delicate component.
If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period.
Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
Other r
eq
ues
ts
accordance with the scope of the technical parameters.
Please read the manual carefully before using.
BLX-5 X Ray Machine
Features:
1.) The tube voltage frequency of this machine is 30 KHz, and the tube current is 0.2 MA. The radiation scope is at an angle of 24 degrees, located within a distance of 1.2 meters ahead.
2.) Toshiba 0.3mm x 0.3mm micro-focus tube
3.) No protective operation room is needed when installing the complete machine
4.) Flexible adjustment of position and angle of handpiece
5.) Compact in volume, light in weight, convenient for carrying
6.) Time is adjustable, high contrast of picture, imaging in focus
7.) There are vacuum components and high-pressure parts inside of the machine, so for your safety and the maintenance of the machine
8.) The tube head is equipped with excellent radiation-shield protection (except the radial mouth, and tests have shown that the radial index is zero. Safety is guaranteed.
9.) Non-film inspection and storage can be realized when corresponding to a sensor
Specifications:
Voltage: 110v±10% and 220V±10%
Power: 24V 8000MA
Charger: 220V/110V, 50Hz
Tube current: 0.1mA
Rating: 60W
Frequency: 30 KHz
Exposure time: 1-9 seconds optional
Leak radiation: < 20μgy/h(12lb)
Focus Skin Distance: >20cm
Tube voltage: 60KV
Relative Humidity(RH) < 80%
Storage conditions: 5-40 degrees Celsius, relative Humidity
Net weight: 5.5 kg
Dimension: 47 x 42 x 19 cm
Content:
Main Unit x 1
Dental Film Position x 1
Charger x 1
Dental Films for Test x 5
English Manual x 1
Warranty Card x 1
Operation of the Main Unit
1. Upon receiving, open the box and check the product for possible damage during shipping.
2. Make sure the fittings on the encasement list are packaged within the box.
3. Connect the six-core cable (of the Main Unit) to the joint of the ball head and tighten the screw
4. After the Main Unit and ball head are perfectly fit together, plug in the international standard electrical source, grounding is strongly recommended.
5. Turn on the Power; the pilot lamp will be light up.During this time, the digital tube of the main unit will show the fore setting time. Now the equipment is in standby mode.
6. Setting the time (Skip to next step if unneeded) Use the "SET", "+", and" -" buttons to reset the time as follows: press SET, the pilot lamp above is illuminated, the machine is now in the time setting mode→then press "+" and" -" to set the time needed (time range is 0.5-9seconds); press set again when the time is adjusted the light lamp is off. The equipment is now in standby mode.
7. Put the Tooth film plumb behind the tooth which is going to be taken picture, and be as close as possible (the smooth side stick to the tooth)
8. Keep the ball head plumb to the tooth projection position; Have the ball head, tooth, and tooth film steadily mutually plumb.
9. After positioning, use theEXP on the main Unit, the remote controller, or the button on the touch head tube to take pictures. The three methods have the same effect. (Notice: gently press)
10. After exposure to the tube, release the start button again (available in three ways) in case of an emergency to stop shooting and return to standby status. (At this point there was no output ray, so the dental films can be used again).
Repeat step 6 to reset the picturing time.To repeat the picturing process, please repeat steps 7 to 9.
11. Turn the power of the main unit off when the work is finished, press POWER, making sure the pilot lamp is off. Don't keep the main unit long in standby mode.
Points for Attention
1.
Make sure the angle of film, tooth, and ball head are properly aligned when taking a picture. Keep them steady until the last step of picturing; making sure that there is no change in any of their positions.
2.
Remember to turn the power offwhen work is done.
3.
Change the battery if the remote controller loses its functioning or if the remote's distance is shorted.
4.
After turning the power on, wait one minute before taking pictures, this allows the ray to provide a steady output.
5.
The equipment switches into protection mode automatically when the voltage is incorrect. If this occurs, it will not be able to carry out the normal work of filming.
6.
When taking pictures, the EXP button could stop the objection and then the machine goes back to the preparation mode.
7.
Use high quality tooth film and developing liquid to make clear pictures.
8. Handle the ball head gently while in use, so as not to damage the delicate component.
9.
Do not pull hard on the cable which connects the ball head to the main unit.
10.
The cable connecting the ball head to the main unit cannot bear the weight of the ball head, so do not raise the ball head by holding the cable, it will cause damage.
11.
We usually set the time between 3-8 seconds when taking pictures, but the actual time of ray output is 0.2-0.5 seconds.
12.
If a situation occurs, preventing the machine from taking regular pictures, contact the seller to solve the problem instead of trying to service the product yourself.
13.
Keep the tooth film and the liquid in a proper place and use them within the shelf-life period. While, because the liquid is not allowed to ship by carrier normal, so we take it out before ship, look forward to your understanding.
14.
Development of films should be performed at temperatures ranging between 23-25 degrees Celsius to ensure the image quality.
15.
Other requests accordance with the scope of the technical parameters.
16.
Please read the manual carefully before using.
FDA Statement
The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. If so, you can bid on this item only if you are an authorized purchaser. If the item is subject to FDA regulation, I will verify your status as an authorized purchaser of this item before shipping of the item.
Seller name:Usadental
City,State:SHENZHEN,China
Telephone number:0755-67530389
Statement:The sale of this item may be subject to regulation by the U.S. Food and Drug Administration and state and local regulatory agencies. So you can bid it on this item only if you are an authorized purchaser. If the item is subject to FDA regulation,We have to verify your status as an authorized purchaser of this item before shipping of the item. Thanks for your understanding!
Payment
We only accept paypal payment,it is easy and safe. and for any other payment forms,please kindly contact us in advance.
Shipping
The goods you ordered will be posted out in the second working day after the payment has been made. (We will inform you via email if any delay occurred due to holiday events.General shipping time is between 7-12 working days. (After the shipping started, the order will be monitored and the track of the item will be posted on paypal)
About Us
If you have any query or dissatisfaction, please find our customer service via eBay Message Center only.If you send message via eBay message, we'll reply you within 24 working hours.
Thank you so much for your purchase. Wish you have a nice day! : -)